Power Foundry™ Technology


Trigeneration + BESS

GridFree AI - The Future of AI Data Center Power.

Power Foundry Trigeneration + BESS System Diagram
Power Generation
10+2 (5x9s)
BESS Capacity
100 MWh
Data Center
~100MW
Cooling
N+1 Redundant

Features

  • Scale Enables Industrialized Power and Cooling
    Modular design allows deployment at gigawatt scale with proven components
  • Proven Technology – No Bespoke Elements
    Every component is battle-tested technology from leading manufacturers
  • Engineered for 5x9 Redundancy and Resiliency
    N+1 redundancy across all systems ensures 99.999% uptime
Environmental Leadership

Off-Grid Power Generation

GridFree's Power Foundry™ generates primary power completely off-grid, eliminating dependence on utility companies and reducing strain on public infrastructure

Independent Power Generation

Our on-site power generation means we don't buy or use power from utility companies. Every watt is produced directly at the data center campus, ensuring complete energy independence.

Zero Grid Impact

By operating completely off-grid, we eliminate the burden on local utility infrastructure. Our data centers don't compete with residential or commercial users for power resources.

Energy Security

Off-grid operation provides complete protection from grid outages, brownouts, and utility disruptions. Your operations remain unaffected by external power issues.

0%
Grid Dependency
100% self-generated power
100%
On-Site Generation
Complete energy independence

Environmental Responsibility

Our off-grid approach not only provides operational advantages but also demonstrates environmental stewardship. By generating power on-site with high-efficiency trigeneration, we achieve superior energy utilization while reducing transmission losses and infrastructure strain. This allows communities to preserve their utility capacity for residential and commercial needs, while we deliver the massive power requirements of modern AI data centers through our independent Power Foundry™ system.

System Components

An integrated approach combining power generation, energy storage, and intelligent cooling

Power Generation

Independent From The Grid with options for LNG, CNG, or pipeline gas, providing energy security and flexibility.

Switchgear & Power Distribution

Advanced switchgear manages electricity flow throughout the system, ensuring reliable distribution to the data center and BESS with intelligent load balancing.

BESS - 100 MWh

Battery Energy Storage System provides instant backup power, load balancing, and seamless transition during maintenance or unexpected events.

N+1 Redundant Chiller Plant

Waste heat from power generation drives absorption chillers, providing efficient cooling without additional energy costs while maintaining N+1 redundancy.

How Power Foundry™ Works

A revolutionary approach to data center power that combines multiple proven technologies into one integrated system

Trigeneration at Scale

Our Power Foundry™ uses natural gas turbines to generate electricity while capturing waste heat for cooling and heating. This trigeneration approach achieves efficiency levels impossible with traditional power generation.

  • Primary Power Generation
    High-efficiency gas turbines produce electricity at gigawatt scale
  • Waste Heat Recovery
    Exhaust heat powers absorption chillers for efficient cooling
  • Overall Efficiency
    Combined heat and power efficiency exceeds 80%
80%+
System Efficiency
99.999%
Uptime Guarantee

Battery Energy Storage Systems (BESS)

Integrated BESS provides instant backup power and load balancing, ensuring continuous operation even during maintenance or unexpected events.

  • Instant Backup Power
    Seamless transition during turbine maintenance or failure
  • Load Balancing
    Smooths power delivery and handles demand spikes
  • N+1 Redundancy
    Multiple battery systems ensure continuous operation

Why the Power Foundry™ Wins

Our integrated approach delivers advantages that traditional power solutions simply cannot match

Gigawatt Scale

Modular design allows deployment from hundreds of megawatts to multiple gigawatts, scaling with your data center needs.

24-Month Deployment

Proven components and streamlined processes enable full deployment in 24 months, compared to 5-7 years for traditional solutions.

5x9 Reliability

N+1 redundancy across all systems ensures 99.999% uptime, meeting the most demanding SLAs for mission-critical operations.

Integrated Cooling

Waste heat powers absorption chillers, providing efficient cooling without additional energy costs or infrastructure.

Proven Technology

No bespoke components - every element is battle-tested technology from leading manufacturers, eliminating custom engineering risks.

Technical Specifications

Enterprise-grade performance metrics designed for the most demanding data center operations

1-5 GW
Power Capacity Range
80%+
Overall Efficiency
99.999%
Uptime SLA
24 mo
Time to Deployment

Ready to Learn More?

Discover how Power Foundry™ can transform your data center infrastructure